Description
Durable digital single channel ECG recorder. Records and displays veterinary ECG waveforms.
Digital isolation technology minimizes environmental artifact and ensures the
validity and reliability in signal processing.
Features automatic adjustment for
baseline drift and automatic analysis and measurement for routine
electrocardiogram parameters.
Features:
- Digital isolation technology minimized
signal interference
- Wide Screen LCD with 3 leads or 1 lead
waveforms display
- Built-in rechargeable battery, AC/DC
supply
- High resolution and precision thermal
array printer
- 8 ECG data and waveforms store and recall
- Adjustable baseline width for convenience
in observation
- Professional software packages for cat,
dog, and horse
Specification
Main
Machine:
- Mode of Leads: Standard 12 leads
- Acquistion Method: 12 leads ECG signals
synchronized acquistion
- Input Method: Floating input with
defibrillation protection and pacing pulse restraint functions
- Classification of Safety: Category I, CF type
applied part
- Input Circuit Current: <0.1UA
- Input Impedance: >50M
- Patient Leakage Current: >10UA
- Time Constant: >3.2S
- Frequency Response: 0.05-150Hz
- Minimum Signal to be detected: <20UVp-p
- Standard Sensitivity: 10mm/Mv
- Calibration Voltage: 1mV
- Anti-polarization Voltage: +-500MV
- Line Input: Single Input; Input Impedance - >100K; Input Sensitivity - 10mm/V
- Line Output: Single Output; Output Impedance - <100; Output Sensitivity - 1V/mV
- Sensitivity: 2.5mm/mV, 5mm/s,
25mm/s, 50mm/s
- Recording Speed: 6.25mm/s, 12.5mm/s,
25mm/s, 50mm/s
- Recording Mode: Manual Mode…Singel
channel, two channels (with rhythm channel); Automatic Mode…Single
channel, two channels (with rhythm channel)
- Parameters Measured: Heart rate, PR
period, QRS time limit, QT/QTC period, P/QRS/T electric axis, RV5/SV1
amplitude
Recorder:
- Recording Method: Thermal Dot Matrix
Word Printing System
- Resolution: >8dots/mm (in
vertical direction); >16dots/mm(25mm/s);
>8dots/mm (50mm/s) (in horizontal direction)
- Specification of recording paper: Paper roll with the
width of 50mm
Monitor:
- Monitor: LCD, white color,
with backlight - Resolution 240x128
- Content Displayed: Lead waveform; Working status information
Others:
- Leads: Standard 12 leads
- Power Supply: AC: 100-240V,
50/60Hz, 40VA; DC: 12V 1800mAh,
Ni-MH battery
- Specification of Tube Fuse: 2-o5x20mm AC time-lag
fuse
T800mA/250V
Accessories:
- Patient Cable
- Limb electrode
- Power cable
- Grounding cable
- Thermal recording paper